Pharmaceutical Analysis Unit -4 MCQs with Answers
1.Which of the following expression is correct for half wave potential
E1/2 = E°+0.0590/n log [Dox/Dred]1/2
E1/2 = E°+0.0591/n log [Dred/Dox]1/2
E1/2 = E°+0.0591 /n log [Dred /Dox]2/3
E1/2 = E°+0.0691 /n log [Dred/Dox]1/2
SOLUTION
E1/2 = E°+0.0591/n log [Dred/Dox]1/2
2.Conductometry is the measurement of
Conductivity of the solution
EMF of the solution
Current across the solution
Voltage across the solution
SOLUTION
Conductivity of the solution
3.Ilkovic equation is used for which purpose
Qualitative purpose
Quantitative purpose
Both a & b
None of the above
SOLUTION
Quantitative purpose
4.The oxidation no. of Cr in K2Cr2O7 is
+6
+7
+5
+4
SOLUTION
+6
5.The electrochemical method which is used to measure electro motive force is called as
Amperometry
Conductometry
Polarography
Potentiometry
SOLUTION
Potentiometry
6.Polarography is developed by which of the following scientist
Hull
Jaroslav heyrovsky
Schiebold
Einstein
SOLUTION
Jaroslav heyrovsky
7.Precision is usually expressed in terms of
Variance
Standard deviation
Sigma method
RSD
SOLUTION
RSD
8.EDTA method of calculating hardness of H20 can be help to detamine
All types of hardness
Temporary hardness only
Permament hardness only
Alkaline hardness only
SOLUTION
All types of hardness
9.In Gas-liquid phase chromatography, the stationary phase is composed of _____ or the mobile stage is made of _____
Solid, liquid
Liquid, liquid
Liquid, gas
Solid, gas
SOLUTION
Liquid, gas
10.The precision under the selfsame operating conditions over a short interval of time is known as
Reproducibility
Intermediate precision
Repeatability
Robustness
SOLUTION
Repeatability
11.The number of moles of a solute per liter of a solution is
Molality
Normality
Molarity
None
SOLUTION
Molarity
12.Which one always acts as oxidizing agent
HNO3
MnO2
H2O2
SO2
SOLUTION
HNO3
13.following Which procedure is used for the Limit test for arsenic
Gutzeit method
Oswald method
Arrhenius method
Karl-Fischer method
SOLUTION
Gutzeit method
14.Which not be used as adsorbent in Column adsorption chromatography
Magnesium oxide
Silica gel
Activated alumina
Potassium permanganate
SOLUTION
Potassium permanganate
15.In which of the following classes of paper, chromatography does the mobile phase pass horizontally over a circular sheet of paper?
Ascending paper chromatography.
Descending paper chromatography.
Radial paper chromatography.
Ascending – descending chromatography.
SOLUTION
Radial paper chromatography
16.The closeness of agreement betwixt a series of calculation obtained from multiple sampling of the homogenous sample is
Accuracy
Precision
Ruggedness
Robustness
SOLUTION
Precision
17.The equivalent weight of NaoH is
36
20
40
13
SOLUTION
40